Cat 6 23/1 AWG UTP FR-LSNH Ethernet Cable | 2131NH

BLANKOM 2131NH

Cat 6 UTP Ethernet data cable, AWG23/1, FRNC/LSNH halogen-free

Color

Grey (RAL7035)

Put-up

250m, 500m, 1000m reel

Availability

BLANKOM cables are available through our distributors
For direct ordering, MOQ and MOV conditions apply
White Label and OEM manufacturing possible

Share this product

BLANKOM Cat 6 23/1 AWG UTP FR-LSNH Ethernet Cable | 2131NH

IEEE 802.3: 10Base-T, 100Base-T, 1000Base-T, ISDN, TOKEN RING 4/16 Mbit, 100 VG, AnyLAN, TP-PMD, TP-DDI, ATM Power over Ethernet (PoE) / PoE+. These cables are used in data communication networks with 250 MHz bandwidth capacity. Halogen-free.
  • Category 6
  • Inner conductor: 23/1 AWG solid annealed bare copper wire
  • PE insulated conductor: 0.99 mm Ø
  • Shielding: U/UTP
  • Outer sheath: FR-LSNH PVC
  • Outer diameter: 6.05 mm Ø

 

Cable design

Conductor…….annealed bare copper……. 0,55 mm

Insulation …… foam-skin PP…………….. Ø0,99 mm

Color code…….1.pair……………………… Blue / White

                          2.pair…………………. Orange / White

                          3.pair ……………... Green / White

                          4.pair……………….. Brown / White

Sheath…………LSNH………………….…. Ø6,05 mm

Electrical Data

Impedance……..……………………………… 100 ± 15 Ω (1-100 MHz), 100 ± 20 Ω (100-250 MHz)

Capacitance………………………………………… Nominal 48 pF/m

Mutual Capacitance (1 kHz)…………………. 48 pF/m

Resistance………..DC………………………. 95 Ω / km

Velocity ratio…………………………………………… 0.69 c

 

General Data

Temperature……operating…………………. -20  +70°C

Bending radius… operating…………………….. 60 mm

Delivery length……………………………… 500mt / reel

Color…………………………………….. GREY (RAL7035)

 

References

Standards…………………………………………………. IEC 61156-5 / EN 50288-6-1

Flame Retardant Test……………………………….. EC60332-1-2 / VDE 0482-332-1-2 / EN 60332-1-2

Smoke Density Test………………………………….. EC61034-2 / VDE 0482-1034-2 / EN 61034-2

Test of Corrosiveness of Com. Gases………….. EC60754-2 / VDE 0482-267-2-3 / EN 50267-2-3

Halogen-Free Test……………………………………. EC60754-1 / VDE 0482-267-2-1 / EN 50267-2-1

Flame Propagation Test…………………………….. EC60332-3-25 / VDE 0482-332-3-25 / EN 60332-1-25

All of our products conform to RoHS directives

Attenuation NEXT    Power Sum

           NEXT

Return Loss  Power Sum               ,                      ANEXT ELFEXT Power Sum ACRF
 

 

MHz

dB/100mt max. dB min.   dB min. dB min.    dB /100mt dB/100mt min. dB/100mt min.
1 2.0 74.3 72.3 20.0 67.0 68.0 67.8
4 3.8 65.3 63.3 23.0 67.0 56.0 55.8
10 6.0 59.3 57.3 25.0 67.0 48.0 47.8
16 7.6 56.2 54.2 25.0 67.0 42.0 43.7
25 9.5 53.3 51.3 24.3 67.0 38.4 39.8
100 19.8 44.3 42.3 20.1 62.5 28.0 27.8
200 29.0 39.8 37.8 18.0 56.5 20.0 21.8
250 32.8 38.3 36.3 17.3 52.0 14.0 19.8

 

Specifications are subject to change without prior notice.