Cat 6 23/1 AWG UTP FR-LSNH Ethernet Cable | 2131NH

BLANKOM 2131NH

Cat 6 UTP Ethernet Data cable, AWG23/1, FRNC/LSNH halogenfree

Color

Grey (RAL7035)

Put-up

250m, 500m, 1000m reel

Availability

BLANKOM cables are available through our distributors
For direct ordering, MOQ and MOV conditions apply
White Label and OEM manufacturing possible

Share this product

BLANKOM Cat 6 23/1 AWG UTP FR-LSNH Ethernet Cable | 2131NH

IEEE 802.3: 10Base-T, 100Base-T, 1000Base-T, ISDN, TOKEN RING 4/16 Mbit, 100 VG, AnyLAN, TP-PMD, TP-DDI, ATM Power over Ethernet (PoE) / PoE+. These cables are used in data communication networks with 250 MHz bandwidth capacity. Halogenfree.
  • Category 6
  • Inner conductor: 23/1 AWG Solid annealed bare copper wire
  • PE insulated conductor: 0.99 mm Ø
  • Shielding: U/UTP
  • Outer sheath: FR-LSNH PVC
  • Outer diameter: 6.05 mm Ø

 

Cable design

Conductor…….annealed bare copper……. 0,55 mm

Insulation …… foam-skin PP…………….. Ø0,99 mm

Color code…….1.pair……………………… Blue / White

                          2.pair…………………. Orange / White

                          3.pair ……………...Green / White

                          4.pair……………….. Brown / White

Sheath…………LSNH…………………. ….Ø6,05 mm

Electrical Data

Impedance……..……………………………… 100 ± 15 Ω (1-100 MHz), 100 ± 20 Ω (100-250 MHz)

Capacitance………………………………………… Nominal 48 pF/m

Mutual Capacitance (1 kHz)…………………. 48 pF/m

Resistance………..DC………………………. 95 Ω / km

Velocity ratio…………………………………………… 0.69 c

 

General Data

Temperature……operating…………………. -20  +70°C

Bending radius… operating…………………….. 60 mm

Delivery length……………………………… 500mt / reel

Color…………………………………….. GREY (RAL7035)

 

References

Standarts…………………………………………………. IEC 61156-5 / EN 50288-6-1

Flame Retardant Test……………………………….. EC60332-1-2 / VDE 0482-332-1-2 / EN 60332-1-2

Smoke Density Test………………………………….. EC61034-2 / VDE 0482-1034-2 / EN 61034-2

Test of Corrosiveness of Com. Gases………….. EC60754-2 / VDE 0482-267-2-3 / EN 50267-2-3

Halogenfreenes Test…………………………………. EC60754-1 / VDE 0482-267-2-1 / EN 50267-2-1

Flame Propagation Test…………………………….. EC60332-3-25 / VDE 0482-332-3-25 / EN 60332-1-25

All of our products conform to RoHS directives

AttenuationNEXT   Power Sum

           NEXT

Return Loss Power Sum               ,                      ANEXTELFEXTPower Sum ACRF
 

 

MHz

dB/100mt max.dB min.  dB min.dB min.   dB /100mtdB/100mt min.dB/100mt min.
12.074.372.320.067.068.067.8
43.865.363.323.067.056.055.8
106.059.357.325.067.048.047.8
167.656.254.225.067.042.043.7
259.553.351.324.367.038.439.8
10019.844.342.320.162.528.027.8
20029.039.837.818.056.520.021.8
25032.838.336.317.352.014.019.8

 

Specifications are subject to change without prior notice.